Description
DETAILS | CNE-9-1-AST10-XSA |
---|---|
Introduction
|
– High-precision pulse width modulation , optional 1~4 channels of combined chassis – Provide working power for mass flow controllers or flow meters – Manual operation control for flow setting – Display of gas flow – Can be used in conjunction with other models of mass flow controllers – Wide voltage range, anti-interference ability by CE certification |
Introduction
|
AST10-XSA type flow indicator is used to provide working power for mass flow meter / mass flow controller, flow setting (manual operation control), the flow indicator is directly connected with the mass flow controller produced by our company (AST10 series) (MFC) supporting use. It can also be used in conjunction with other models of mass flow controllers. They may be connected up to four MFC , and each have their brightest display. Easy to use, optional embedded / desktop installation, exquisite and beautiful.
|
Technical Parameters (Electrical characteristics – Power supply)
|
165V ac ~ 265V |
Output voltage (used by MFC)
|
+15V ± 3% , -15V ± 3%
|
Input / output signal
|
DC 0~5V , 4~20 mA optional
|
Display unit
|
SCCM (standard ml/min): SLM (standard l/min)
|
External control
|
Cleaning / closing
|
Display characteristics
|
One way display, two way display, three way display, four way display
|
Dimensions
|
Single channel: 96 X 96 X 173mm , multi-channel: 483 X 140 X 210mm
|
Hole Size
|
Single channel: 92 X 92 mm , multi-channel: 442 X 124 mm
|
Datum source
|
+5.00V 5mA
|
Maximum power consumption
|
Maximum power consumption: single channel 15W, multi-channel 45W
|
weight
|
Single channel: 1Kg, multi-channel: maximum 7.5kg
|
Serial Number
|
AST10-XSA flow display controller
|
Product type
|
[01] Single channel
[02] Two channels [03] Three channels [04] Four channels |
Valve control function
|
[01] Yes
[02] None |
Input / output signal
|
[V] 0~5VDC
[A] 4~20mA |
Chassis type
|
[T] Desktop
[P] Plate |
Selection examples
|
AST10-XSA 04 01 V T
|
Reviews
There are no reviews yet.